[{"command":"settings","settings":{"basePath":"\/","pathPrefix":"","setHasJsCookie":0,"ajaxPageState":{"theme":"iaqa_u","theme_token":"q4ZL8Agmbs-XPgsUEnoa43YNNyD-qRHiV3plH8Za1PQ","jquery_version":"1.10"},"CToolsModal":{"loadingText":"Loading...","closeText":"Close Window","closeImage":"\u003Cimg typeof=\u0022foaf:Image\u0022 class=\u0022img-responsive\u0022 src=\u0022https:\/\/university.iaqa.org\/sites\/all\/modules\/contrib\/ctools\/images\/icon-close-window.png\u0022 alt=\u0022Close window\u0022 title=\u0022Close window\u0022 \/\u003E","throbber":"\u003Cimg typeof=\u0022foaf:Image\u0022 class=\u0022img-responsive\u0022 src=\u0022https:\/\/university.iaqa.org\/sites\/all\/modules\/contrib\/ctools\/images\/throbber.gif\u0022 alt=\u0022Loading\u0022 title=\u0022Loading...\u0022 \/\u003E"},"edu-modal-style":{"modalSize":{"type":"fixed","width":"auto","addHeight":700,"height":"auto"},"modalOptions":{"background-color":"black"},"closeText":"\u003Ci class=\u0022fa fa-times-circle\u0022 title=\u0022Close\u0022\u003E\u003C\/i\u003E","loadingText":"","modalTheme":"edu_modal_theme","animation":"fadeIn","animationSpeed":"medium","throbberTheme":"edu_modal_throbber"},"better_exposed_filters":{"views":{"course_modal":{"displays":{"block":{"filters":[]}}}}}},"merge":true},{"command":"modal_display","title":"Build it Tight Let\u0027s Get it Right","output":"\u003Cdiv class=\u0022view view-course-modal view-id-course_modal view-display-id-block view-dom-id-4cb94b29fc538b398fd5a95955c6a89f\u0022\u003E\n \n \n \n \u003Cdiv class=\u0022view-content\u0022\u003E\n \u003Cdiv class=\u0022views-row views-row-1 views-row-odd views-row-first views-row-last\u0022\u003E\n \n \u003Cdiv class=\u0022views-field views-field-field-edu-body\u0022\u003E \u003Cdiv class=\u0022field-content\u0022\u003E\u003Cp\u003EThis presentation will talk about some case studies on building design and constructions where build it tight and did not ventilate it right had caused sweating\/condensation leading to mould growth. We will look at three projects where we see water like droplets in the ceiling cavity or walls from thermal break failure or tightness issue. The misunderstanding by some project leaders who continue to make mistakes because of the lack of understanding in buildings such as with passive house design or ventilation strategy requirements. The case sturdy will include the hypothesis in the undertaking of the investigation, the IAQ strategy plans and the analytical report that support one of the indoor air quality complaints that the occupant smelled \u201ca fishy and fragrant smell\u201d, this continued after mouldy material was removed from this passive house building.\u003C\/p\u003E\n\u003C\/div\u003E \u003C\/div\u003E \u003C\/div\u003E\n \u003C\/div\u003E\n \n \n \n \n \n \n\u003C\/div\u003E"}]